Category Archives: SIBATA

SIBATA SCIENTIFIC

Manual Vaccum Pump

Manual Vaccum Pump,This hand vacuum pump is used to check for leaks from the flow line during daily inspections for MP-Σ series products.,

Item Code 080870-10
Exhaust Rate
15ml/1stroke
Dimensions/Weight
200(W)x50(D)x200(H)mm 500g
Accessories
plumbing tube 1unit
Price (excluding tax) Contact us
Note  

,

Dust Jar Model H

Dust Jar Model H,Collecting dust fall using a dust jar has the advantage of easy handling and simple transport. It is also inexpensive and is not affected by the wind.

This product complies with the standard methods of analysis for hygienic chemists, annotation 2005.,

Item Code 080080-07
Model Model H
Mass
18kg
Composition
Glass cylinder outer diameter Dia. 165 mm x height 220 mm (inner diameter Dia. 157 mm)
Stand with support 405 (W) x 400 (D) x 1700 (H) mm
Price (excluding tax) Contact us
Note  

Options and Spare Parts

Glass Cylinder Dia.165 for Dust Jar
080080-072

Glass Cylinder Base Dia.137 for Dust Jar
080080-073

Glass Cylinder Cap Dia.165
080080-074

Dust Jar Glass Cylinder Dia.137×250
080080-052

,

Digital Dust Indicator LD-5D

Digital Dust Indicator LD-5D,The LD-5D uses a sheathed air detector mechanism and includes a built-in suction pump. It is a relative concentration indicator with a light scattering system, and can perform measurements at tunnel construction sites and other worksites with comparatively high dust concentrations.

Relative concentration must be corrected to mass concentration by determining the mass concentration conversion factor (K value) with the filtration collection method as the standard. However, the mass concentration conversion factor is preloaded into the LD-5D, so the measurement value can easily be converted to the mass concentration for display. Note that this indicator has comparable characteristics to existing dust indicators (laser light source types), so mass concentration conversion factors to date can be used at equivalent worksites.

• This product is compatible with the calibration standards of the Japan Association for Working Environment Measurement.

● Thanks to the sheathed air mechanism, there are no concerns about contamination of the optical system, and it can be used to provide stable measurements at work sites with high dust concentrations.

● A large filter has been adopted, so it is capable of extended use even for high concentration measurements.

● The extent of filter contamination can be confirmed visually.

● Entering a K value in advance enables the measurement value (CPM) displayed to be converted to mass concentration (mg/m3).

● A span check and background measurement prior to dust measurements automatically maintain the sensitivity at time of shipment.

● Measurement values (CPM) can be recorded in the main unit. (In logging measurement mode)

● The recorded measurement values can be loaded into a PC and saved in text format using the USB cable and communication software provided.

● During measurement, a voltage or pulse corresponding to the concentration is output.

● It can be powered by dry cells or an AC adapter.

● It can be attached to a commercially available tripod.,

Item Code 080000-5
Model LD-5D
Measurement Principle
Light Scattering Method
Measurement Range
0.01~100.0mg/m3
Measurement Accuracy
±10%(Against standard particle)
Light Source
Laser Diode
Measurement Sensitivity
1CPM=0.01mg/m3(for calibration particles)
Measurement Mode
Countdown timer: Measurement is set and performed using a built-in countdown timer.
6 sec, 10 sec, 30 sec, 1 min, 2 min, 3 min, 5 min, 10 min (The default when the instrument is turned ON is 1 minute countdown mode.)
Output
USB/RS-232C output (by exclusive communication cable with software)
Pulse output:Open collector Maximum voltage capacity : 12V
Analog output:0-1V(3 ranges selectable), output impedance 100Ω
Display
graphicLCD Screen(With backlight, contrast can be adjusted)
Display Content
Accumulated count display:0~99999count(99999and above:continue counting from 00001)
Mass concentration conversion value display: mg / m3
/Measurement time /Current time /Measurement mode /Battery level / K value (set value 0.1 to 9.9)
/Bar graph (instantaneous value is displayed by pressing the switch during measurement)

Operating Environment
Temperature 0-40ºC, Relative humidity 5-90%(Provided there is no condensation)
Power Supply
(1) DC12V from 8 size C dry cell batteries (2)Special AC Adapter
Dimensions/Weight
245(W)x90(D)x190(H)mm(ExcluDing protrusions), Approx. 2.88kg(Include battery)
Accessories
Shoulder belt, AC adapter (PA-314), communication cable with software (USB), AA manganese dry cell x 8
Price (excluding tax) Contact us
Note  

Options and Spare Parts

Capsule Filter LAS-1 for LD-5D
080000-55

,

Sterile Filter Unit MICROCHECKII

Sterile Filter Unit MICROCHECKⅡ / white / 50 pcs,Microcheck III Sterile Filter Unit

Cylinder Cover: The Microcheck II is a sterile filter unit. Remove the cover when sampling bacteria, and use it again as a lid when cultivating the bacteria.

Cylinder: A membrane filter is fastened between the base and the cylinder.

Base: This container supports a membrane filter with a pore size of 0.45 μm, and an absorption pad that retains the liquid culture medium during cultivation. A combined air intake port and culture medium injection port is on the bottom of the base.

,

Item Code 080110-098
Price (excluding tax) Contact us
Note  

,

Communication Cable with Software S-USB

Communication Cable with Software S-USB,This is a communication cable with software for LD-3B, LD-3K2, and LD-5D digital dust indicators.

Check the OS compatibility before use.Compatible OS for the communication cable with software: Windows 8.1/10,

Item Code 080000-415
Model For LD-3B/LD-3K2/LD-5D
Operating Environment
Windows 8.1/10
Price (excluding tax) Contact us
Note  

,

Residual Chlorine Test Kit / DPD method/ 100 reagent

Residual Chlorine Test Kit / DPD method/ 100 reagent,This comparator uses a simplified measurement method based on the unique reaction that occurs when a DPD reagent is added to water containing residual chlorine and the color of the water changes to light reddish purple depending on the amount of residual chlorine. You add the reagent once. (When measuring total residual chlorine, you add reagents twice as the optional potassium iodide is also used.)

This comparator can identify free residual chlorine and total residual chlorine.

Main Applications

・ To control residual chlorine in tap water for drinking, swimming pools for regular swimming or competitions

・ To control residual chlorine in public bathes or hot springs as a measure against legionnaires’ disease

・ To control total chlorine of water for dialysis

● DPD reagent is a powder reagent and is individually packed so one bag is used each time. Standard reagent package for 100 tests and economy pack for 500 tests are available.

● As DPD reagent contains a pH buffer, it adjusts the pH of sample water so that the color can be measured in a stable condition. (Measurements can be performed stably when the pH of sample water is between 3 and 10).

● When the optional potassium iodide reagent is also used, total residual chlorine can be measured. The combined residual chlorine concentration can be calculated from the difference between the total residual chlorine concentration and free residual chlorine.

● As the expiration date of the reagent is printed on the box, you can easily check if the reagents have expired.

● As the color comparison plate can be removed, the product can be managed easily and economically.

Measurement Method—For Residual Chlorine (Free Residual Chlorine)

・ Fill two rectangular test tubes with sample water until they are 80 % full and place them into the left and right test tube pockets on the main unit.

・ Pour 10 mL of sample water into the remaining rectangular test tube.

・ Add the DPD powder reagent and mix it.

・ Place the sample water in the center hole for color comparison measurement.

Measurement Method—For Combined Residual Chlorine

・ After measuring free residual chlorine, add one spoonful (0.1 to 0.5 g) of the separately available potassium iodide using the dispensing spoon provided, and dissolve it.

・ Leave the solution for approximately 2 minutes. Then, insert it into the center test tube pocket of the residual chlorine comparator, compare the color against the colors on the color comparison plate, and find the concentration of total residual chlorine from the applicable standard color.

・ Obtain the combined residual chlorine concentration using the calculation formula.

Combined residual chlorine (mg/L) = Total residual chlorine (mg/L) – Free residual chlorine (mg/L),

Item Code 080540-521
Measurement Method
DPD method
Colorimetric Version
0.05 0.1 0.2 0.3 0.4 0.5 mg/L
0.6 0.8 1.0 1.3 1.5 2.0
DPD Powder Reagent
prvided (100 tests)
Mass
0.3kg(Including case)
Size
Main unit : 67(W)x37(D)x156(H)mm
Vinyl case : 97(W)x50(D)x170(H)mm
Composition
Residual chlorine meter body (with 12 types of color plates) x 1 unit
Square test tube with silicon cap x 3
Vinyl case x 1
DPD powder reagent 100 times x 1 box
Price (excluding tax) Contact us
Note  

Options and Spare Parts

DPD Powder Reagent / 100 pks
080540-501

DPD Powder Reagent / 500 pks
080540-503

DPD Color Comparator / residual chlorine testing
080540-522

Residual Chlorine Comparator Test Tube / 3 pcs
080540-0210A

Water Quality Testing Potassium Iodide / 20 g
080520-0058

Residual Chlorine Comparator Test Tube Cap
080540-0220A

Residual Chlorine Comparator Case
080540-023

,

Dust Fall Sampler Deposit Gauge

Dust Fall Sampler Deposit Gauge,This sampler is installed outdoors and collects rainwater and precipitates. Normally, rainwater that accumulates in the container is separated out by evaporation, and the substances in the air are analyzed. A wire mesh is placed over the top to protect the funnel and keep away birds.

The stand splits into a top and bottom half, which is convenient for transport and storage.,

Item Code 080080-011
Dimensions/Weight
Dia. 600×1150(H)mm, Approx. 19kg
(Height at separation Approx. 610mm)
Composition
Frame Wire mesh stand Dia. 600mm
Dust repellent (made of vinyl chloride)
Hard glass funnel Dia. 300mm
Screw cap bottle 20L GLS-80 with blue CAP
Price (excluding tax) Contact us
Note  

Options and Spare Parts

Deposit Gauge Dust Protection
080080-2

,

Dust Jar Model H

Dust Jar Model H,Collecting dust fall using a dust jar has the advantage of easy handling and simple transport. It is also inexpensive and is not affected by the wind.

This product complies with the standard methods of analysis for hygienic chemists, annotation 2005.,

Item Code 080080-07
Model Model H
Mass
18kg
Composition
Glass cylinder outer diameter Dia. 165 mm x height 220 mm (inner diameter Dia. 157 mm)
Stand with support 405 (W) x 400 (D) x 1700 (H) mm
Price (excluding tax) Contact us
Note  

Options and Spare Parts

Glass Cylinder Dia.165 for Dust Jar
080080-072

Glass Cylinder Base Dia.137 for Dust Jar
080080-073

Glass Cylinder Cap Dia.165
080080-074

Dust Jar Glass Cylinder Dia.137×250
080080-052

,