Air Sampler Mini Pump MP-sigmaNⅡ series

Air Sampler MINIPUMP Model MP-sigma30NⅡ,MP-Σ (sigma) series products are small, light-weight, portable high-performance air suction pumps (air pump) equipped with the accumulated flowrate measurement function. As basic types, three types for 0.5 L/min, 3 L/min, and 5 L/min are available by flowrate range. As their suction flowrate is stable, they can be widely used for sampling hazardous substances in work environments, indoor environments, air environments, etc.

● The product is equipped with a flow sensor so it can directly measure the suction flowrate and digitally display the instantaneous flowrate and accumulated flowrate.

● Constant flowrate functionality is included to inhibit suction flowrate drops associated with suction pressure increases, such as when collecting dust.

● Timer sampling can be performed in four modes (manual, countdown timer, volume timer, and cycle timer).

● The LC display has a backlight so you can check the displayed content such as flowrate even in a dark place.

● The level of backup filter contamination can be checked visually.

● It is equipped with a measurement data recording function and ten past measurement results can be checked on the main minipump unit as well as the computer.

• A quick charger (QC-10N) is not included.,

Item Code 090860-034
Model MP-Σ30NⅡ
Measurement Mode
Manual, countdown timer, volume timer, cycle timer
Communication
Data import and setting using dedicated communication software
Pump Method
Double diaphragm type
Flow Accuracy
Within ±5 % of the set flowrate value
Flowmeter
Mass flow sensor
Material
Pump head: ABS, POM, TPU, Diaphragm: EPDM, Valve: EPDM, Case: PC
Variable Flow Rate Range
0.050∼0.500L/min
Constant Flow Rate Usage Range
0.1L/min:0∼10.0kPa
0.2L/min:0∼9.0kPa
0.3L/min:0∼9.0kPa
0.4L/min:0∼8.0kPa
0.5L/min:0∼7.0kPa
Time Setting/Display
Year/month/day, hour:minute
Intake And Exhaust Ports
Outer diameter DIA.6mm and DIA.8mm (tubes used: inner diameter DIA.5 and 7mm)
Instantaneous Flow Rate Display Range
0.000~0.750L/min
Mass
0.65kg(Including lithium-ion secondary battery)

Time Settings
0.00~999.59(hours.minutes)
Display
Display Unit LCD (with backlight)
Cumulative Flow Setting Range
0.00-999.99L
Cumulative Flow Rate Display
0.00-9999.9L
Operating Environment
Temperature 0-40ºC, Relative humidity 10-90%(Provided there is no condensation)
Power Supply
Lithium-ion rechargeable battery(option), AA dry cell batteries, (need Dry cell battery unit)(option), AC adapter(option)
Size
145(W)x67(D)x95(H)
Accessories
Lithium-ion rechargeable battery, Suction holder for ultra-low flow rate
Price (excluding tax) Contact us
Note  

Options and Spare Parts

Dry Cell Battery Unit DB-10N
080860-011

Battery Unit LI-10N
080860-010

Quick Charger QC-10N
080860-110

MP-sigmaN Series Suction Holder
080860-002

MP-sigmaN Series Soft Case
080860-003

MP-sigmaN/N2 Communication Cable with software
080860-0045

Filter Element VFE-3 / 5 pcs
080860-001

Air Sampler MINIPUMP Model MP-sigma30NⅡ
090860-034

Impinger Holder for MP series
080840-53

MP Series Filter Holder Fitting
080140-603

PM Series Rubber Adaptor
080870-0016

,

SIBATA Air Sampler Mini Pump MP-sigmaNⅡ series

SIBATA Air Sampler MINIPUMP Model MP-sigma30NⅡ,MP-Σ (sigma) series products are small, light-weight, portable high-performance air suction pumps (air pump) equipped with the accumulated flowrate measurement function. As basic types, three types for 0.5 L/min, 3 L/min, and 5 L/min are available by flowrate range. As their suction flowrate is stable, they can be widely used for sampling hazardous substances in work environments, indoor environments, air environments, etc.

● The product is equipped with a flow sensor so it can directly measure the suction flowrate and digitally display the instantaneous flowrate and accumulated flowrate.

● Constant flowrate functionality is included to inhibit suction flowrate drops associated with suction pressure increases, such as when collecting dust.

● Timer sampling can be performed in four modes (manual, countdown timer, volume timer, and cycle timer).

● The LC display has a backlight so you can check the displayed content such as flowrate even in a dark place.

● The level of backup filter contamination can be checked visually.

● It is equipped with a measurement data recording function and ten past measurement results can be checked on the main minipump unit as well as the computer.

• A quick charger (QC-10N) is not included.,

Item Code 090860-034
Model MP-Σ30NⅡ
Measurement Mode
Manual, countdown timer, volume timer, cycle timer
Communication
Data import and setting using dedicated communication software
Pump Method
Double diaphragm type
Flow Accuracy
Within ±5 % of the set flowrate value
Flowmeter
Mass flow sensor
Material
Pump head: ABS, POM, TPU, Diaphragm: EPDM, Valve: EPDM, Case: PC
Variable Flow Rate Range
0.050∼0.500L/min
Constant Flow Rate Usage Range
0.1L/min:0∼10.0kPa
0.2L/min:0∼9.0kPa
0.3L/min:0∼9.0kPa
0.4L/min:0∼8.0kPa
0.5L/min:0∼7.0kPa
Time Setting/Display
Year/month/day, hour:minute
Intake And Exhaust Ports
Outer diameter DIA.6mm and DIA.8mm (tubes used: inner diameter DIA.5 and 7mm)
Instantaneous Flow Rate Display Range
0.000~0.750L/min
Mass
0.65kg(Including lithium-ion secondary battery)

Time Settings
0.00~999.59(hours.minutes)
Display
Display Unit LCD (with backlight)
Cumulative Flow Setting Range
0.00-999.99L
Cumulative Flow Rate Display
0.00-9999.9L
Operating Environment
Temperature 0-40ºC, Relative humidity 10-90%(Provided there is no condensation)
Power Supply
Lithium-ion rechargeable battery(option), AA dry cell batteries, (need Dry cell battery unit)(option), AC adapter(option)
Size
145(W)x67(D)x95(H)
Accessories
Lithium-ion rechargeable battery, Suction holder for ultra-low flow rate
Price (excluding tax) Contact us
Note  

Options and Spare Parts

Dry Cell Battery Unit DB-10N
080860-011

Battery Unit LI-10N
080860-010

Quick Charger QC-10N
080860-110

MP-sigmaN Series Suction Holder
080860-002

MP-sigmaN Series Soft Case
080860-003

MP-sigmaN/N2 Communication Cable with software
080860-0045

Filter Element VFE-3 / 5 pcs
080860-001

Air Sampler MINIPUMP Model MP-sigma30NⅡ
090860-034

Impinger Holder for MP series
080840-53

MP Series Filter Holder Fitting
080140-603

PM Series Rubber Adaptor
080870-0016

,