Sediment Dust Regenerator SKY-2 Set,This instrument regenerates workplace sediment dust collected, reproducing normal airborne dust sampling conditions. The PM4 particles are then collected using a particle size separator.
● By regenerating sediment dust in the workplace, PM4 particles can be recollected in order to create samples for X-ray diffraction analysis.
● The C-30 multi-stage particle size separator or the NW-354 inertial impactor can be used to collect PM4 particles efficiently.
● In order to adjust the horizontal positioning of the C-30 multi-stage particle size separator, an adjuster is attached to the base of the SKY-2 regenerator.
● In order to check that the C-30 multi-stage particle size separator is level, a leveling instrument is attached to the C-30 attachment unit (C-30 adapter).
● A reducing adapter can be attached to the C-30 multi-stage particle size separator to enable the use of a dia. 25 mm filter.
● The sampling flowrate when recollecting PM4 particles is 9.6 L/min for the C-30 and 20.0 L/min for the NW-354.
● The sampling pump used when recollecting PM4 particles is separately available. In order to accurately recollect PM4 particles, use a suction pump to ensure a stable suction volume.,
Item Code | 080200-52 | |
---|---|---|
Model | SKY-2 | |
Size |
420(W)x260(D)x780(H)mm | |
Composition |
SKY-2 type main body of accumulated dust recurrence dust device (With double ball of impinger stand) (080200-513) Different diameter adapter for SKY (with 25mm filter paper clip) (080200-512) Multi-stage separator (Model C-30) (080050-3553) Inpaction Particle Size Separator (080120-354) SPC Midget Impinger (080030-5) |
|
Price (excluding tax) | Contact us | |
Note |
Options and Spare Parts
,